Name:8-inch Linux System Temperature Measurement and Face Recognition Terminal Kiosk
Model:LW-800-T
Size:8-inch IPS Tempered Screen
Face Recognition:Support
Temperature Measurement:Support
Operating System:Linux

Product Description

Specification


LCD   Display

Model

LW-800T

Diagonal   Size

8   inch

Resolution

800   x 1280

View   Angle

170°W/170°H

Brightness

400cd/

Face   Camera

Image   Sensor

Dual   Lens, High performance image sensor,1 / 2.8”progressive CMOS

Lens   Focus

6mm

Pixel   Pitch

2.0MP@30fps

Min   Illumination

Color   0.01Lux @F1.2(ICR);B/W 0.001Lux @F1.2 (ICR)

White   Balance

Yes

SNR

50db(AGC   OFF)

WDR

120db,   ISP algorithm face partial exposure

Temperature   Sensor

Sensor   Module

Germany   Imported Sensor

Detection   Distance

0.3m~0.8m

Field   angle(FOV)

33°

Array   Resolution

32   x 32

Deviation   Range

±0.3

Recognition   Pattern

Pop   up alarm while human body temperature exceeds set value.

Face   Recognition

Recognition   Accuracy

99.8%

Recognition   Speed

300ms

Liveness   Recognition

support

Mask   Recognition

support

Face   Database Capacity

24000

Face   Capture Records

160000

System   Parameter

Operating   System

Linux   System

System   Storage

1G   ROM/16G EMMC

External   Storage

Support   TF card

Recognition   Mode

Face   recognition, face mask recognition, temperature detection

Software

Backend   Attendance System

Interface

1x10/100BaseT   RJ45/1xWiegand/1xrelay/1xRS485/1xUSB/1XGPIO

Speaker

8Ω   2W

Pickup

Capacitive   electret microphone

Housing

Material

Aluminum   housing, optical tempered glass

Surface   Painting

Eco-friendly   painting

General

Working   Temperature

-30℃   --60  

Working   Humidity

10%-90%

Power   Consumption

5W

Power   Supply

DC12V/2A

Outline   Dimension

252mm   x 136mm x 26mm

weight

1.7kg

Access Interface

image.png

image.png



Notes. 

*The temperature measuring device should be used in a room with no ventilation and room temperature between 16 ℃ -40 ℃. *

The temperature measurement accuracy will affect if people entering indoors from a cold outdoor environment. * 

Please run the device 10 minutes after the sensor temperature and ambient temperature are balanced to start testing. 

*Please make sure that there is no heating source or air conditioning vent within 3 meters of the device. *

Please taking temperature after leaving the forehead unobstructed for three minutes indoors when the temperature is stable. *

Please do not exposure forehead under the situation such as showers, hair dryers, sprays, etc. It will affect the measurement. *

The forehead temperature will be lower than the actual temperature if there is oil on the forehead, makeup, oxygen mask, or wrinkles in the elderly. 

* Please make sure there is no hair or clothing covering the area where the projection is located.


System Arichitecture


image.png




image.png





image.pngimage.png


Hits: 【Print】 
Pre:21.5 inch Hand Saniztier LCD Kiosk     Next:75 inch LCD Interactive Whiteboard with IR Touch